热门搜索: 50072ATAT1, GST-tag Recombinant 40520ATF2, GST-Tag Recombinant 31114GCN5 (727-837), His-tag Recombinant 50074GCN5 (KAT2A), FLAG-tag Recombinant 50071p300 (KAT3B), His-GST-tag Recombinant 11004ACHE, His-Tag Recombinant BS电子游戏2019娱乐平台 100077BCL2A1, His-Tag Recombinant 100080BCL2L10, His-Tag Recombinant 100091BCL2L2, His-Tag Recombinant 80113Caspase6, His-tag Recombinant 70000Caspase7, His-tag Recombinant 80114Caspase8, His-tag Recombinant og彩票娱乐平台 100054MALT1, FLAG-Tag (Mouse) Recombinant 100637MCL-1 His-Tag (Mouse) Recombinant

OPUS娱乐平台 / Product display

您的位置:首页  /  OPUS娱乐平台   /    /  PDE Assay Kits  /  60321PDE2A Assay Kit

PDE2A Assay Kit

●Purchase●DescriptionThePDE2AAssayKitisdesignedforidentificationofPDE2Ainhibitorsusingfluorescencepolarization

  • 产品型号:60321
  • 厂商性质:生产厂家
  • 更新时间:2023-11-11
  • 访  问  量:170
立即咨询

联系电话:

详细介绍
Purchase
Description

The PDE2A Assay Kit is designed for identification of PDE2A inhibitors using fluorescence polarization. The assay is based on the binding of a fluorescent nucleotide monophosphate generated by PDE2A to the binding agent. PDE2A catalyzes the hydrolysis of the phosphodiester bond in dye-labeled cyclic adenosine monophosphate (cAMP). Nanoparticle beads selectively bind the phosphate group in the nucleotide product. This increases the size of the nucleotide relative to unreacted cAMP. Since the degree of polarization of a fluorophore is inversely related to its molecular rotation, dyes attached to the slowly-rotating nucleotide-bead complexes will not have time to reorient and therefore will emit highly polarized light. Conversely, dyes attached to the rapidly-rotating cyclic monophosphates will obtain random orientations and emit light with low polarization.

The key to the PDE2A Assay Kit is the specific binding agent. Using this kit, only two simple steps on a microtiter plate are required for PDE2A reactions. First, the fluorescently labeled cAMP is incubated with a sample containing PDE2A1 for 1 hour. Second, a binding agent is added to the reaction mix to produce a change in fluorescent polarization. The FP signal is measured using a fluorescent microplate reader capable of measuring fluorescence polarization.

60321

Synonyms
PDE2A, phosphodiesterase 2A, PDE2
留言询价

留言框

  • 产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 省份:

  • 详细地址:

  • 补充说明:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7
关注公众号

邮箱:infocn@bpsbioscience.com

传真:

地址:上海静安区

Copyright © 2025 10大信誉娱乐平台下载    备案号:   技术支持:化工仪器网

TEL:

扫码加微信
Baidu
map